Element
Description
The current condition of each type of error gets indicated. Green means no error, red
indicates that an error has been detected.
At the occurrence of a type of error for which the checkbox DETECT is ticked, the
COLLECTED ERROR: DPC DEVICE flag is set at the same time and the FAULT-LED output
of the CSK is activated.
DEVICE CONNECTED
The PCA bus connection between DPM and CSK is broken.
SLOT POSITION
The call station kit is not connected to the correct slot position.
MEMORY
Memory error in CSK.
WA CLEAR
Watchdog error in CSK. This error type is logged according standards, press the button
connected to ESC_K to reset the error.
FIRMWARE
The firmware version of the CSK is to old.
MICROPHONE
Microphone error in CSK.
IRIS-Net
PROMATRIX 8000 | en 815
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956