The SWEEP button puts the tone generator in sine sweep mode.
The constant frequency of a sine signal.
The start frequency of a sine sweep.
The stop frequency of a sine sweep.
The time in seconds, it takes the sine signal to sweep through the
range marked by the start frequency and the stop frequency.
Activates the periodical repetition of a sine sweep.
-35 dB
-60... 0 dB
Fader for setting the signal level.
-35.0 dBu
or
0.014 V
-60...0 dBu or
0.001...0.775
V
Entering the signal level is possible in dBu or V.
Switch for activating or deactivating the tone generator.
ASCII Control Protocol
RS-232 SETTINGS
The RS-232 interface of the device is preconfigured for full duplex operation. Set values are:
Parameter
Setting
Baud Rate
19200 bits per second
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
Xon / Xoff
The command string "*** <device> command mode entered ***" is sent to RS-232 once the device is powered up and
has completed its boot sequence. The RS-232 interface is now ready for communication.
ETHERNET SETTINGS
Factory set values of the Ethernet port are:
Parameter
Setting
IP address
192.168.1.100
Network mask
255.255.255.0
IRIS-Net
DIGITAL MATRIX | en 455
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956