Jobs
For amplifiers to be able to communicate with each other, it is possible to send and receive Job Codes. In principle, a
job code is a function number that an amplifier transmits via OMNEO and that is received and interpreted by another or
several other amplifiers. Each amplifier is capable of transmitting and receiving up to 5 different job codes.
Programming job codes is nearly identical to the programming of control inputs and outputs.
!
Caution!
Job codes make the remote triggering of functions from one amplifier to another very convenient
by sending remote commands over the network. This can reduce cabling and make installation
easier. The job code transmission mechanism in the RCM-28 uses UDP, which does not have the
same delivery confirmation and retransmission characteristics as TCP. Due to this, while the
operation and transmission of these codes is generally very stable and reliable, there is a very
small chance that a message may be lost due to heavy network traffic. If job code or GPI
functionality is needed for a mission-critical or life safety application, it is recommended to use a
network with enough free bandwidth and make sure that no other heavy network traffic can
occur, or to use direct hardwiring to GPIs on each amplifier instead of job codes.
Consequences
Receive Jobs: A receive job is a function that is carried out as soon as the corresponding function number (the Receive
Job Code) is received.
Example:
This example shows the programming of four Receive Jobs. Jobs No. 1 and 2 switch the amplifier’s power on or off
while jobs No. 3 and 4 select presets U03 or U02. The fifth Receive Job has not been configured.
–
Receive Job Nr. 1: Power on (receiving Job Code 1 switches the amplifier’s power on)
–
Receive Job Nr. 2: Power off (receiving Job Code 2 switches the amplifier into stand-by mode)
–
Receive Job Nr. 3: Preset U03 (receiving Job Code 3 selects preset U03)
–
Receive Job Nr. 4: Preset U02 (receiving Job Code 4 selects preset U02)
Element
Default
Range
Description
Receive
Job No
0
1...1023 Here, you can specify which incoming job code numbers a specific amplifier
recognizes. Entering random numbers between 0 and 1023 is possible.
Function
(empty)
This column allows assigning an individual function to each job code received.
Clicking the desired line in the Function menu opens a dialog field that shows all
accessible functions. The table "Input and Receive Job Functions" lists all functions
together with their individual settings.
Parameter
(empty)
Here you can set the different function parameters. For more information, please
refer to the table "Input and Receive Job Functions".
Opt. Value
(empty)
Certain functions allow specifying optional parameter values.
IRIS-Net
REMOTE AMPLIFIER | en 254
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956