Channel identification
A click with the right mouse button on this field opens the Copy &
Paste menu, which allows copying all master delay parameters of
the selected input to any other master delay within the same
project.
2.0 ms
2.0...1000
ms
DELAY allows delaying the corresponding input channel’s audio
signal by an adjustable period of time.
HINT: The amplifier accepts settings up to a total delay time of
1365ms per channel, including Master Delay and X-OVER Delay.
If a comparably long alignment delay has already been set for the
X-OVER, the delay time that is available for the master delay
scan fall below 1000ms!
BYPASS allows activating (button not engaged) or deactivating
(button engaged) the corresponding delay.
General Parameters
Element
Default
Range
Description
ms
ms, samples, ft, in,
m, cm,
µs, s
This lets you select the unit of measurement for the delays.
20 °C
-20...60 °C or
-4...140 °F
Entering the actual ambient temperature is possible here. In case you
have chosen a distance value as unit of measurement for the delay,
delay times are corrected in relation to temperature. Temperatures
can be entered as °C or °F.
Editing Delays by Dragging the Mouse in the Graphics Display
The graphics display shows the corresponding speaker symbol in color as soon as a delay has been activated. Clicking
with the left mouse button onto the speaker icon and keeping the mouse button pressed allows dragging the symbol to
the right or the left, which results in a change of the selected channel’s delay time. A delay’s title lights in color as soon
as the mouse cursor is positioned on top of the corresponding icon to provide improved overview and handling.
CHANNEL EQ
Both output channels of a remote amplifier employ 5-band parametric equalizers each, mainly for speaker equalization.
Except for the possibility to select All pass as filter type, these filters are identical to the ones of the master-EQ's.
The Channel-EQ is selected by clicking on the fifth block of the flow diagram selector or by double clicking on the
CHANNEL EQ block in the full-scale flow diagram.
IRIS-Net
REMOTE AMPLIFIER | en 128
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956