Amplifier & Channel Labels
Element
Description
The labels of an amplifier and its input and output channels are shown in a clear
structure. All labels can be edited. Changes are immediately reflected in the different
panels and windows (amplifier control panel, flow diagram, and overview).
CAUTION: Using*(asterisk) and/or = (equal) signs in a name is not permissible.
SWITCHING AUDIO INPUTS AUTOMATICALLY
RCM-26 remote amplifiers allow automatic switching from the AES feed to the analog input in the case of failure of the
AES signal or input. This feature allows a redundant analog signal to be fed to the amplifier and automatically switch
over to the “backup” signal without user intervention.
Open the Modify Properties dialog from the context menu of the RCM-26 remote amplifier in the IRIS-Net worksheet.
Following table lists the relevant properties for automatic audio input switching.
Property
Default
Range
Description
Audio Input Switching. AES
Fail. Enable
0
0, 1
Set the value to 1 to enable the auto fall back function
which switches from AES to analog input in case of an AES
error. This property corresponds to the „Auto Switch
Enable“ control found in the Config & Info window.
Audio Input Switching. AES
Fail. Time
1 s
0 to 120 s
Configures the duration the AES error had to be present on
the input to trigger the AES / analog switching.
Audio Input Switching. AES
Good. Enable
0
0, 1
Setting this property to 1 enables the automatic switching
from analog input to AES input in case the AES signal is
OK.
HINT: This works only if the values of both properties –
Audio Input Switching. AES Fail. Enable and Audio Input
Switching. AES Good. Enable-are set to 1.
Audio Input Switching. AES
Good. Time
5 s
0 to 120 s
Configures the duration the AES signal had to be in
„Locked“ state, to switch back from analog to the AES
input.
Audio Input Switching. AES
Ok Flag
0
0, 1
Shows that the AES signal is locked and without errors for
longer than the configured Audio Input Switching. AES
Good Time.
Audio Input Switching. AES
Selected Flag
0
0, 1
Shows that the AES input is used as amplifier audio input.
Audio Input Switching.
Counter
0
-
Counts how often the Auto Switch ganged the input.
IRIS-Net
REMOTE AMPLIFIER | en 184
Bosch Security Systems B.V.
User Manual