VALUES
Element
Description
The Input Analog block is a variable input parameter for rational numbers which always
outputs the current value of the connection.
The Output Analog block is an output parameter for rational numbers. The value at the
input of this block is assigned to the connection.
The IO Analog block is a variable input and output parameter for rational numbers. The
value at the input of this block is assigned to the connection. The block always outputs
the current value of the connection.
The Virtual Analog block has the same behavior as the IO Analog block, but has no
connection property. Instead the rational number assigned to the
‚Value‘ property of the block will be sent to the output.
The Constant Analog block is a constant input parameter for a rational number. The
rational number entered in the „Value“ property of the block at Task Engine
configuration time will always be sent to the output. This enables the block to provide a
constant to other task engine blocks.
The Input Logic block is a variable input parameter for Boolean values which always
outputs the current value of the connection.
The Output Logic block is an output parameter for Boolean values. The value at the
input of this block is always assigned to the connection.
The IO Logic block is a variable input and output parameter for Boolean values. The
value at the input of this block is assigned to the connection. The block always outputs
the current value of the connection.
The Virtual Logic block has the same behavior as the IO Logic block, but has no
connection property. Instead the logic value entered in the ‚Value‘ property of the block
will be sent to the output.
The Constant Logic block is a constant input parameter for a Boolean value. The
Boolean value entered in the „Value“ property of the block at Task Engine configuration
time will always be sent to the output. This enables the block to provide a constant to
other task engine blocks.
The Calendar Entry blocks is a variable input parameter for Boolean values. The value at
the output of this block depends on the configuration of the block and the system time
of the N8000.
ANALOG OPERATIONS
Element
Description
The rational number at the output of the Addition block is always the sum of rational
numbers of the (wired) inputs. Not all inputs have to be wired.
IRIS-Net
DIGITAL MATRIX | en 334
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956