LIMITS OF THE PROMATRIX 8000 SYSTEM
Property
DPM 8016
System with n DPM 8016 (n
max
= 10)
Speaker zones, in total
500
1000
–
Lines (A/B) per zone
2
Priority relays, in total
1800
3600
–
per zone
5
Control relays, in total
1800
3600
–
per zone
5
Groups, in total
500
Call stations per PCA port
4
Call stations, in total
16
n * 16
Background music program (without
audio network)
1
n
Remote control amplifiers per DPM
99
n * 99
Amplifier output channels
396
n * 396
Input modules (with two audio
channels each)
8
n * 8
Output modules (with two audio
channels each)
8
n * 8
DCS 801R
15
n * 15
DCS 408R or DCS 409R connected to
a DCS 801R
17
n * 17
DCS 412R connected to a DCS 801R
5
n * 5
DCS 412R, in total
75
n * 75
Logical inputs, in total 500 n * 500
500
n * 500
DCS 416 connected to a DCS 801
5
n *5
DCS 416, in total
75
n * 75
Supervised inputs from a central fire
alarm system
30
n * 30
Relay modules, in total (DCS 408 or
DCS 409)
255
n * 255
Number of relays, in total
2000
n * 2000
Task Engine blocks
1024
n * 1024
Task Engine connections per block
48
Network channels
16
IRIS-Net
PROMATRIX 8000 | en 721
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956