Commands for CAN-BUS communication
Read
Write
Values
Description
/PARAM /CAN
/MONITOR
/VALUE
R
error! (unknown
channel),
INPUT_A RCM: X,
INPUT_B RCM:
X,OUTPUT_A
RCM:X,
OUTPUT_B RCM:
X
Input or output channel of
amplifier (with CAN address
X) currently selected for
monitor bus
/SCANSTATE /VALUE
R
SCAN_FAILED,
SCAN_READY
State of CAN-BUS after scan
/FUNCTIONS /CAN_RESET exec
none
Reset of CAN-BUS
/CAN_SCAN
exec
none
Scan CAN-BUS for new devices
/SET_BAUD_
ALL
exec
10, 20, 63, 125,
250, 500
Set new Baud rate of the
device and all devices
connected to the CAN-BUS
/SET_
MONITOR
exec
input_a, input_b,
output_a,
output_b; 1-250
Selects Monitor Bus of a
remote amplifier
Commands for system queries
Read
Write
Values
Description
/PARAM /LOCAL /
CHASSISTEMP
/VALUE
R
Device temperature in degree Celsius
/FANSPEED
/VALUE
R / W
0, 1, 2, 3
Fan speed (0 = off, 1 = slow, 2 = mid,
3= fast)
/GPIANALOG
/
IDX1...IDX4
R
0, 1
State of GPI using analog circuit
/GPIDIGITAL
/
IDX1...IDX4
R
0, 1
State of GPI using digital circuit
/GPO
/
IDX1...IDX3
R / W
0, 1
State of GPO (0 = open, 1 = closed)
/
REMOTEFAUL
T
/
IDX1...IDX1
00
R
0, 1
State of remote device (0 = OK, 1 =
does not answer)
/
CONDRESULT
/
IDX1...IDX1
00
R
0, 1
State of condition (0 = false, 1 = true)
IRIS-Net
DIGITAL MATRIX | en 457
Bosch Security Systems B.V.
User Manual