Keyword
Values
Default
Description
OpenIntActive
0, 1
0
This keyword allows activating or deactivating the ASCII
Control Protocol. If deactivated, a connection via Ethernet is
not possible.
–
OpenIntActive = 1: The ASCII Control Protocol is activated
–
OpenIntActive = 0: The ASCII Control Protocol is not
activated
OpenIntPort
6273
The Ethernet port for the TCP connection between the
Controller and the external device.
Following table lists the default setting of the Controller’s Ethernet port.
Parameter
Default
IP address
192.168.1.100
Network mask
255.255.255.0
Standard gateway
192.168.1.1
Port
6273
HINT: Only one single Ethernet connection can be used at one time.
HINT: The password protection of the ASCII Control Protocol can be configured at the Interfaces dialog of the
Controller.
ZONE STATUS
Whenever the output status of the local zones changes, a zone status string is sent via the ASCII Control Protocol. The
format of the zone status string is: <Idx.y> <Change> <Pm> <Zone Pattern>
Element
Description
Idx.y
Unique identifier:
x is the number x in the IRIS-Net internal device name, e.g. „Device_x“
y is a unique paging request number of the local Controller
Change
ON, if the paging request Idx.y has activated one or more local audio outputs of the Controller
OFF, if the paging request was terminated and the corresponding local audio outputs of the
Controller have been deactivated
Pm
Priority of the paging request
Zone Pattern
List of activated local zones of the Controller.
Examples:
Id3.7 ON P12 Z2-3
Id3.7 OFF
Notice!
The zone pattern lists the zone numbers, this numbers can be found in the Line Supervision table
of the DPM 8016