Function
Parameter
Range
Description
NOTHING
No function
POWER
Controls Power On / Stand-by
../PRM/
SWITCH
ON
Switched the amp's power to ON
OFF
Switches the amp in Stand-by mode
FLIP
Toggles between ON and Stand-by and vice versa
ABS
Sets the selected DSP parameter to an absolute value
../PRM/IDX
100...1A5
Selects the DSP parameter via index number
../PRM/
VALUE
Relative change of the parameter
REL
Changes the selected DSP parameter in relation to the actual value
../PRM/IDX
100...1A5
Selects the DSP parameter via index number
../PRM/
VALUE
Relative change of the parameter
TOGGLE
Toggles a DSP parameter between 0 and 1 (this only makes sense for
flag parameters, e.g. MUTE, BYPASS, etc.)
../PRM/IDX
100...1A5
Selects the DSP parameter via index number
PRESET
Loads a DSP preset
../PRM/NR
1...8, F1
Selects an user preset U01 to U08 or a factory preset F01
MONI
Controls the selection for the audio monitoring bus
../PRM/SEL
NONE, RELAY,
IN_A, OUT_A, IN_B,
OUT_B
Selects audio monitoring parameters. All combinations are possible.
../PRM/
SWITCH
ON, OFF
Switches the selected audio monitoring parameter ON or OFF
GFRES
Deletes stored Ground Fault flags in selected channels
../PRM/CHAN A, B
Any combination of output channels is possible
MEMFLAG
Manipulates general Memo flags
../PRM/CLR
NONE, 1...16
Clears selected flags
../PRM/
TOGGLE
NONE, 1...16
Changes the state of selected flags. Use CLR and TOGGLE together,
so that selected flags are set afterwards.
MEAS
Initiates impedance testing at a fixed frequency
../PRM/
FREQU
10...20000 [Hz]
Generator frequency for impedance test
../PRM/
GAIN_A
-128...+50 [dBu]
Generator level for impedance test in channel A