This example shows the programming of four Receive Jobs. Jobs No. 1 and 2 switch the amplifier’s power on or off
while jobs No. 3 and 4 select presets U03 or U02. The fifth Receive Job has not been configured.
–
Receive Job Nr. 1: Power on (receiving Job Code 1 switches the amplifier’s power on)
–
Receive Job Nr. 2: Power off (receiving Job Code 2 switches the amplifier into stand-by mode)
–
Receive Job Nr. 3: Preset U03 (receiving Job Code 3 selects preset U03)
–
Receive Job Nr. 4: Preset U02 (receiving Job Code 4 selects preset U02)
Element
Default
Range
Description
0
1...1023 Here, you can specify which incoming job code numbers a specific amplifier
recognizes. Entering random numbers between 0 and 1023 is possible.
(empty)
This column allows assigning an individual function to each job code received.
Clicking the desired line in the Function menu opens a dialog field that shows all
accessible functions. The table "Input and Receive Job Functions" lists all functions
together with their individual settings.
(empty)
Here you can set the different function parameters. For more information, please
refer to the table "Input and Receive Job Functions".
(empty)
Certain functions allow specifying optional parameter values.
HINT: Programming identical control functions or receive jobs for several amps is easily accomplished by creating
Programming identical control functions or receive jobs for several amps is easily accomplished by creating a group
that includes all the desired amps and afterwards perform the programming in the group’s Configuration&
Information dialog. All settings are automatically applied to all amplifiers of that group, which saves time and effort
and additionally reduces the risk of programming errors.
Transmit Jobs: Transmit Job defines a function number that is sent as soon as a specific internal event (condition)
occurs in the amplifier.
Example:
This example shows the programming of four Transmit Jobs. Jobs No. 1 and 2 are triggered by control input 1. Jobs
No. 3 and 4 are triggered by the status signaled from control input 2. The fifth transmit job has not been configured.
–
Transmit Job Nr. 1: GPI IN1 (Job Code 1 is transmitted when control input 1 is closing)
–
Transmit Job Nr. 2: Invert GPI IN1 (Job Code 2 is transmitted when control input 1 opens)
–
Transmit Job Nr. 3: GPI IN2 (Job Code 3 is transmitted when control input 2 is closing)
–
Transmit Job Nr. 4: Invert GPI IN2 (Job Code 4 is transmitted when control input 2 opens)
Element
Default
Range
Description
0
1...65536
Here, you can specify which job code numbers an amplifier transmits on the
occurrence of specific events. Entering random numbers between 0 and 65536
is possible.
IRIS-Net
REMOTE AMPLIFIER | en 187
Bosch Security Systems B.V.
User Manual