A short description of each DSP page is provided in the following table. Please refer to the corresponding chapters for
a more detailed explanation.
Element
Description
Flow Diagram
The signal flow display provides an overview of the DSP settings. This area also includes all
controls for the preset location/file management and configuration settings.
Input Parametric
EQ
The Input Parametric EQ page provides access to the two 10-band parametric equalizers of the
sound system processor inputs.
Input Graphic EQ
The Input Graphic EQ page provides access to the two 31-band graphic equalizers of the sound
system processor inputs.
Input Delay
This page allows the programming of delay lines for the input channels A and B.
Array Parametric
EQ
The Array Parametric EQ page offers access to the 5-band parametric equalizers of the sound
system processor outputs.
Array Delay
This page allows the programming of delay lines for the output channels.
Output Parametric
EQ
The Output Parametric EQ page offers access to the 6-band parametric equalizers of the sound
system processor outputs.
Output X-Over
Frequency crossover-filters as well as the parameters gain and polarity for all output channels are
located in the Output X-Over area.
Output FIR
This page provides a FIR-Filter for each output channel.
Output Delay
This page allows the programming of delay lines for the output channels.
Output Limiters
This page provides access to Peak limiter and TEMP limiter of each output channel.
FLOW DIAGRAM
The Flow Diagram window shows a signal flow diagram, which offers a quick overview of all DSP setting of the DSP
600.
–
Output muting,
–
routing channels,
–
setting output level,
–
editing configuration LEDs (Free Configuration mode only),
–
import and export of Speaker Settings
can be done directly in the diagram. Clicking onto the corresponding function blocks lets you access all other DSP
parameters. All parameters that are necessary for the saving, loading and previewing of presets are also accessible
from this window.
The FLOW DIAGRAM window opens when clicking on the first (IN), fifth (RTG) or 13. block (OUT) in the Flow Diagram
Selector.
IRIS-Net
DIGITAL SOUND PROCESSOR | en 611
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956