MAINS MODE
If mains power is used for running the system, the Controller is in
MAINS MODE and the LED lights green. You can edit the name of this
mode in the text field. Press the POWER button to power on/off the
device.
STANDBY MODE
If the system is in STANDBY MODE, this LED lights green. You can edit
the name of this mode in the text field.
BATTERY MODE
If battery power is used for running the system, the Controller is in
BATTERY MODE and the LED lights green. You can edit the name of
this mode in the text field.
MAINS POWER FAIL
BEHAVIOR
AMPLIFIERS
Select this option if Amplifiers should switch to standby mode if mains
power fails.
CONTROLLER
Select this option if the Controller should switch to standby mode if
mains power fails.
ROUTERS
Select this option if Routers should switch to standby mode if mains
power fails.
SWITCH ON PRIORITY
MAINS MODE
Enter the minimum priority a signal (e.g. chime) must have to switch
the system on, if the system is in standby mode and mains power is
available.
BATTERY MODE
Enter the minimum priority a signal (e.g. chime) must have to switch
the system on, if the system is in standby mode and mains power is
not available (battery mode).
Notice!
The “Power Calculator” tool can be used to calculate the power consumption of the system. The
tool can be found in directory “/Tools” or can be requested from the IRIS-Net support team.
Notice!
The properties “Operating Mode” and “Standby LED” can be used for advanced power
management configuration via the Task Engine, please refer to section Properties, page 788.
LineSupervision Dialog
The Line Supervision dialog allows configuring and control of the Controller line supervision. Line supervision can be
done via line impedance measurement method or the End of Line method using EOL 8001 or Plena EOL modules.
Please refer to the Controller manual for details about the different measurement methods.