Element
Description
This field indicates and allows entering the DCS system address. Left-click in the input field
and enter the desired address in a range from 1 to 15. Press "Return" to apply the address.
The entered address has to correspond to the setting of the address selection switch on the
front panel of the DCS 801R. The DCS system address is exclusive; i.e. it may exist only
once in the system. When creating new DCS Devices in IRIS-Net, addresses are
automatically assigned in ascending order.
Indicates the CAN bus transfer rate when in on-line mode.
Indicates the DCS firmware version when in on-line mode.
UPDATE
Opens the firmware update dialog.
EQUIPMENT
A DCS system may consist of a single, two or three DCS 400 frames. Drag & dop cards from the DCS Objects list to
empty slots to equip the DCS 400 frame. Right click a slot to open the context menu. The context menu includes
commands to equip, delete or move cards.
When equipping these frames, the following rules need to be observed:
–
Frame 1: Slot 1 always has to be equipped with a DCS 801R. IRIS-Net automatically adds a DCS 801R. Rearranging
or deleting the DCS 801R is not possible. If the DCS system consists of only one frame, slots 2 to 10 can be
equipped with the following card types: DCS 408R, DCS 409R, DCS 412R, DCS 416R, DCS 406R. If a second
frame is included, the last slot from the left has to be equipped with a DCS 405R.
–
Frame 2: Slot 1 always has to be equipped with a DCS 405 R. If the DCS system consists of only two frames, slots
2 to 10 can be equipped with the following card types: DCS 408R, DCS 409R, DCS 412R, DCS 416R, DCS 406R. If
a third frame is included, the second frame has to be equipped with a DCS 405R (like in the first frame).
–
Frame 3: Slot 1 always has to be equipped with a DCS 405 R. Slots 2 to 10 can be equipped with the following
card types: DCS 408R, DCS 409R, DCS 412R, DCS 416R, DCS 406R.
–
Number and type of cards in a DCS system: A DCS system can maximally be equipped with 17 relay modules (DCS
408R / DCS 409R), 5 logic input modules (DCS 412R) or 5 analog input/output modules (DCS 416R) respectively.
–
Gaps between individual cards are not allowable. If necessary, gaps have to be filled using cards of the type DCS
406R.
DCS card types
DCS 801R CONTROLLER MODULE
The DCS 801R module is used as an interface for relay boards, logic input boards, analog level
input/output boards, and rotary encoders. Control takes place via REMOTE CAN BUS
interface. A DCS 801R control module can maximally host 17 relay modules (DCS 408R /DCS
409R), 5 logic input modules (DCS 412R), 5 analog input/output modules (DCS 416R), and 2
rotary encoders.
IRIS-Net