(empty)
This column allows assigning an individual function to each job
code received. Clicking the desired line in the Function menu
opens a dialog field that shows all accessible functions. The
table "Input and Receive Job Functions" lists all functions
together with their individual settings.
(empty)
Here you can set the different function parameters. For more
information, please refer to the table "Input and Receive Job
Functions".
(empty)
Certain functions allow specifying optional parameter values.
HINT: Programming identical control functions or receive jobs for several amps is easily accomplished by creating a
group that includes all the desired amps and afterwards perform the programming in the group’s Configuration &
Information dialog. All settings are automatically applied to all amplifiers of that group, which saves time and effort and
additionally reduces the risk of programming errors.
Transmit Jobs: Transmit Job defines a function number that is sent as soon as a specific internal event (condition)
occurs in the amplifier.
Example:
This example shows the programming of four Transmit Jobs. Jobs No. 1 and 2 are triggered by control input 1. Jobs
No. 3 and 4 are triggered by the status signaled from control input 2. The fifth transmit job has not been configured.
–
Transmit Job Nr. 1: GPI IN1 (Job Code 1 is transmitted when control input 1 is closing)
–
Transmit Job Nr. 2: Invert GPI IN1 (Job Code 2 is transmitted when control input 1 opens)
–
Transmit Job Nr. 3: GPI IN2 (Job Code 3 is transmitted when control input 2 is closing)
–
Transmit Job Nr. 4: Invert GPI IN2 (Job Code 4 is transmitted when control input 2 opens)
Element
Default
Range
Description
0
1...1023
Here, you can specify which job code numbers an amplifier
transmits on the occurrence of specific events. Entering
random numbers between 0 and 1023 is possible.
(empty)
This column allows specifying an event (condition) that
triggers the corresponding transmit job code. Clicking the
desired line in the Condition menu opens a dialog field that
shows all accessible functions. The table "Output and
Transmit Job Conditions" lists all functions together with
their individual settings.
(empty)
Here you can set the different function parameters. For more
information, please refer to the table "Output and Transmit
Job Conditions".
(empty)
Certain functions allow specifying optional parameter values.