Limiter Parameters
Element
Default
Range
Description
Default (39
dB)
User, Default (39 dB), Q44,
Q66, CP1200, CP1800,
CP2200, CP3000S, CP4000S,
P1200 (0dBu), P1200 (+6dBu),
P1200 (26dB), P2000 (0dBu),
P2000 (+6dBu), P2000 (26dB),
P3000 (0dBu), P3000 (+6dBu),
P3000 (26dB), TG5 (0dBu),
TG5 (32dB), TG5 (35dB), TG7
(0dBu), TG7 (32dB), TG7
(35dB), Q44 MKII, Q66 MKII,
Q99, Q1212, CPS2.4, CPS2.6,
CPS2.9, CPS2.12
Select the amplifier type connected to output of the
Dx46.
123 Vpk
AMP THRESH determines the audio signal level
above which the peak limiter starts operating.
2 dBu
DSP THRESH determines the audio signal level
above which the peak limiter starts operating. This
value may change depending on the AMP- LIFIER
type that is selected, as the sensitivity and output
power are automatically calculated with the Vpk
value to provide DSP Threshold.
User
User, Hi, Mid, Lo, Sub
TYPE allows a user to select a bandpass type, and
the software will enter appropriate default time
constants for the bandpass selected. Electro- Voice
speaker settings include factory-defined time
constants, so this section is only for use when
creating DSP settings from scratch.
0 ms
0 to 50 ms
ATTACK determines how fast the limiter reduces
amplification when the threshold is exceeded.
100 ms
10 bis 1000 ms
RELEASE determines how fast the limiter returns to
normal amplification, after the audio signal level
declined the threshold.
Press the ACTIVE button to deactivate the peak
limiter.
The ACTIVATED LED lights green if the TEMP limiter
is active.
IRIS-Net
DIGITAL SOUND PROCESSOR | en 688
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956