Function
Parameter
Range
Description
NOTHING
No function
POWER
Interpretation results in "true", when the power amp is powered on
(even during power-on delay) and "false", when the amp's power is off.
ABS
Interpretation results in "true", when the DSP parameter value is higher
or equals the reference value.
../PRM/IDX
100...1A5
Selects the DSP parameter via index number
../PRM/
VALUE
Reference value
TEMP
Interpretation results in "true", when the measured amplifier
temperature is higher or equals the reference value.
../PRM/
CELSIUS
-20...150 [°C]
Temperature reference value
VU
Interpretation results in "true", when at least one of the selected values
is higher or equals the programmed reference value.
../PRM/SEL
IN_A, OUT_A,
ALIM_A,
DLIM_A,
COMP_A, IN_B.
OUT_B, ALIM_B,
DLIM_B,
COMP_B
Any combination of the values listed is possible. ALIM = Amplifier
Limiter
DLIM = DSP Limiter COMP = DSP Compresser
../PRM/DB
[dB]
VU reference value
CTL_IN
Interpretation results in "true", when the selected control input is
activated.
../PRM/IDX
1, 2
Selects a control input
ERRFLAG
Interpretation results in "true", when one of the selected flags is set.
Any combination of the flags listed is possible.
../PRM/MASK POWER
set, when the power is OFF
STANDBY
set, when the amplifier is in Stand-by mode
PROTECT
set, when the amp's Protect mode is activated
OVT
set, when the amp's thermal limit is exceeded
GNDFLT_A,
GNDFLT_B
set, when ground fault has been detected
ZMIN_A,
ZMIN_B,
ZMAX_A,
ZMAX_B
set, when the measured output load is out of limit value range