The Object ID specifies the DSP object of the N8000 to be accessed. It is identical for all call
inputs of a single paging matrix. However, when using a variety of matrixes, the Object ID has to
be different for each matrix. Find the Object ID via Modify Properties --> DSP. Priority
Matrix_x.Connect Paging Line OID of the DSP block Priority Matrix.
This parameter defines the paging matrix input, i.e. the matrix row, which will be used as call
input. The entered value has to be in the range of 1 and 32 because a priority matrix can include
a maximum of 32 rows.
Enter the number of rows of the priority matrix.
Enter the number of columns of the priority matrix.
This parameter defines which types of audio signals (DPM 4000 internal and external) will trigger
a specific input of the paging matrix.
Telnet Setup
The Telnet Setup page allows activating the telnet connection of the device. To activate the telnet connection select
the checkbox “Accept Telnet Connections”, then click Save Settings.
IRIS-Net
DIGITAL MATRIX | en 502
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956