/FNCT
R / W
NOTHING,
POWER,
ABS, REL,
TOG- GLE,
PRESET,
MONI,
GFRES,
MEMFLAG,
MEAS,
TEST- GEN
Function during activation.
For further details please refer to the
table "Control Inputs - GPI Functions"
below.
/PRM
/...
Parameter and values for the functions
mentioned before
/OFF
...
(same as above but for the
deactivation of control inputs)
/IN2
...
(same as above but for the control
input 2)
/OUT1
/
STATE
R / W
ON, OFF
State of the Control Output
/ON
/TIME
R / W
0...10.0 [s] Delay / debounce time for the
programmed condition
/FNCT
R / W
NOTHING,
POWER,
ABS,
TEMP, VU,
CTL_IN,
ERR- FLAG,
MEMFLAG,
PRESET
Condition that activates a control
output.
For further details please refer to the
table "Control Outputs - GPO
Functions" on this page.
/INV
R / W
ON, OFF
Inverts the result of the programmed
condition
/SYNC
R / W
ON, OFF
Lets you select whether the control
outputs can be synchronized using a
special CAN-command.
/PRM
/..
Parameters and values for functions
mentioned above
/OFF
...
(same as above but for switching off a
control output)
/OUT2
...
(same as above but for the control
output 2)
/MEMFLAG /SET
R / W
NONE,
1...16
List of currently set Memo flags
IRIS-Net
REMOTE AMPLIFIER | en 158
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956