DSP Dialog
The DSP window lets the user configure all DSP functions of the P 64. This is possible by selecting DSP-Blocks of the
Processing Objects categories on the left side of the screen and dragging them into the DSP worksheet. DSP-Blocks
can be freely positioned and wired within the worksheet. Double clicking on a DSP-Block’s icon allows editing its
configuration and settings in detail.
Element
Description
The currently active Preset is shown here. Selecting a preset is possible from the Preset List
in the Preset Manager.
The EDITED indicator lights green if the momentarily active settings correspond to the
Preset that had been loaded last. In case parameters of the loaded Preset have been
changed, the EDITED indicator lights red.
Stores the DSP configuration’s current settings in the active Preset.
Opens the Preset Manager.
Represents the hardware configuration of the P 64. Clicking with the right mouse button on
one of the slots, when in off-line mode, allows editing the configuration. The indication
represents the actual configuration when on-line. A red/yellow indicator signals differences
between actual and off-line configuration (see also General Dialog).
This indicates the DSP system’s estimated load. Adding supplementary DSP-Blocks is not
possible when the actual load (DSP LOAD or DSP RAM) reaches 100%. Adding
supplementary Delay-Blocks is not possible when the actual load (DELAY MEM) reaches
100%.
RIGHTS WHEN EDITING THE DSP CONFIGURATION
There are several ways to restrict the rights for editing the DSP configuration of a P 64. Generally, editing the DSP
configuration is only possible when logged-in in IRIS-Net as administrator. Therefore, it is advisable to create additional
user accounts in an IRIS-Net project, besides the administrator account, and to assign appropriate passwords. Please
also refer to the corresponding chapter "Password Protection Of A Project" on .
In addition, there is the option to determine for each single DSP block, whether a user that has no administrator rights
may open the associated configuration dialog box.
IRIS-Net
DIGITAL MATRIX | en 342
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956