AUDIO PROCESSING
Error during the processing of audio data.
MEMORY/DATA
Memory or Read/Write error.
SUPPLY VOLTAGE
Error in the internal power supply unit.
AD CONVERTER
Malfunction of the control inputs’ A/D converters.
TEMPERATURE
Temperature overload of the N8000.
FAN SPEED
Current running speed of the N8000’s fan. Possible fan speeds are Off, Slow,
Med. and High, see table below.
TEMP
Current temperature on the inside of the enclosure.
USER FLAGS
One or more User Flags have been set. CONFIG button for configuring User
Flags.
CAN BUS
Fault condition on the CAN-Bus. The CONFIG button opens the CAN Interface
Faults dialog, see below.
COBRANET
Fault condition on the CobraNet. Further details are provided via the CobraNet
dialog box.
HEARTBEAT FROM
MASTER
Query from the master N8000, which has been programmed to monitor this
N8000, are not received anymore.
HEARTBEAT CHECK
Select this checkbox to check for heartbeat messages from other N8000s.
SLAVE DEVICE
At least one NetMax N8000 that had to be monitored does not react anymore.
The CONFIG button opens a list of N8000 that have been configured as Slave
devices.
REMOTE AMPLIFIERS
A connected Remote Amplifier has transferred an error message. The CONFIG
button opens the CAN Interface Faults dialog, see below.
GPI
The input voltage at a control input (GPI) is too high/low.
DPM 4000
The DYNACORD DPM 4000 that is connected via RS-232 port cannot be
reached anymore.
RS-232 PORTS
Malfunction has been detected for an external device, which is being
monitored via RS-232 port.
INPUT SUPERVISION
(PLT)
Pilot tone recognition fault at the inputs of the N8000. Each input can
separately be configured in the input blocks.
COLLECTED ERROR
STATE
The FAULT-LED on the front panel of the N8000 lights at the occurrence of this
type of error.
IRIS-Net
DIGITAL MATRIX | en 331
Bosch Security Systems B.V.
User Manual