Element
Description
Mode
Select the desired parameter change that is to be executed when pressing the button on the call
station:
–
Set Value = sets the value of the logic variable to "1". It remains "1", even after the button is being
released.
–
Reset Value = sets the value of the logic variable to "0". It remains "0", even after the button is
being released.
–
Push = sets the value of the logic variable to "1", but only as long as the button is being pressed.
–
Toggle = inverts the value of the logic variable each time the button is being pressed.
–
LED only = indicates the value of the logic variable, the value is not changed by the button
On
Select the LED of the button that should indicate the value „1“ of the logic variable:
–
Primary LED (green/red)
–
Secondary LED (yellow)
–
None
Off
Select the LED of the button that should indicate the value „0“ of the logic variable:
–
Primary LED (green/red)
–
Secondary LED (yellow)
–
None
Parameter
The logic variable whose value is being changed. This can be the keyword Pagings.VControl1.Value
which can be used to start a signal. See Pagings Dialog, page 762 on how to configure the conditions
for a logical key.
Active when
locked
Selecting this checkbox allows the user to press the button even though the call station has been
locked.
Arithmetical Key
A switch of the type "Arithmetical Key" allows changing the value of a numerical variable. Pressing the button on the
call station either increases or decreases the value of the numerical variable.
Element
Description
Mode
Select the desired parameter change that is to be executed when pressing the button on the call station:
–
Up = increases the value of the numerical variable
–
Down = decreases the value of the numerical variable
Parameter The numerical variable whose value is being changed.