Commands for Test Generator
/SERVICE
/GEN
/A
/
SWITCH
R / W
ON, OFF
Generator ON / OFF for channel A
/GAIN
R / W
-128...50
[dBu]
Generator output level for channel A
/B
...
R / W
(identical parameters for channel B)
/
MODE
R / W
SINE,
WHITE,
PINK
Test Generator signal type
/
FREQ
U
R / W
10.0...2000
0
.0 [Hz]
Test Generator Frequency, when SINE
has been selected
/MIX
R / W
ON, OFF
Wanted signal and Generator signal
mixed (ON) or Generator solo (OFF)
/PRE
R / W
ON, OFF
Generator signal fed in at the input or
at the output
Examples:
–
/POWER/SWITCH ON switches amp's power on
–
/TEMP/ACT ? queries the amp temperature
–
/TEMP/ACT 65 reply to query: 65 °C
–
/ERRFLAG/ACT ? queries operational state and error flags
–
/ERRFLAG/ACT POWER,GLOBAL reply to query: Power is On, Global Error detected (Collected Error in external
CAN-devices)
–
/ERRFLAG/GLOBAL ? queries for which external CAN-devices errors have been detected
–
/ERRFLAG/GLOBAL 3-4 reply to query: Collected Error Flags on amps 3 and 4 are set
GENERAL DSP PARAMETER DESCRIPTION
Parameter
Value/Settings
Description
level
-128...+6 [dB]
-128dB is identical to MUTE
trim level
-30...+6 [dB]
mute
0 / 1
0 = ON, 1 = MUTE
polarity
0 / 1
0 = Normal, 1 = Invertiert
route
0 / 1 / 2
0 = IN A, 1 = IN B, 2 = IN A+B
delay
Delay value with unit (time or distance)
HINT: Reading displays the delay value independent
of the saved unit. Writing also stores the stated unit.
bypass
0 / 1
0 = ON, 1 = BYPASS
eq type
0...5
0 = PEQ, 1 = LOSHELV, 2 = HISHELV, 3 = LOCUT, 4 =
HICUT, 5 = ALLPASS
IRIS-Net
REMOTE AMPLIFIER | en 162
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956