Deletes the entire Event Log of the selected N8000/P 64 or DPM 8016.
LOG BUFFER FULL
WARNING (N8000/P 64
only)
An entry appears in the Event Log if this checkbox is checked and the Event Log memory of
the device runs low.
USED MEMORY
Displays the available Event Log memory of a the device. 0% indicates that the memory is
empty.
LOGGING START
(DPM 8016 only)
Displays date and time of the first (e.g. oldest) entry in the Event Log.
LAST ENTRY (DPM 8016
only)
Displays date and time of the last (e.g. newest) entry in the Event Log.
LOG FILE(S) (N8000/
P 64 only)
Displays the storage location at which the currently used log file is saved on the PC in
relation to the IRIS-Net installation path.
(N8000/
P 64 only)
Opens a dialog for selecting the log file.
DAYS PER FILE (N8000/
P 64 only)
Number of days after which a new log file is being created.
ENTRIES PER FILE
(N8000/P 64 only)
Number of entries at which, when exceeded, a new log file is being created.
Changing available devices
The devices shown in the Object List can be customized. Use the IRIS-Net Device Options dialog window. The dialog
window opens automatically the first time IRIS-Net is run. For later customization, you can find the dialog window in
the menu Edit > Device Options.
Select the groups of devices that should be available in the Object List. Project files containing devices that are not
selected in this dialog can still be opened and edited.
Remote Control Network / Interface
The network for the Remote Control power amps is based on the CAN-bus standard. This popular protocol has been
used for many years in automotive, industrial and security applications. The CAN-bus is a balanced serial interface for
command and data transmission. Controlling the power amplifiers is performed from a Windows based PC running
IRIS-Net – Intelligent Remote & Integrated Supervision – software. The UCC1 USB-CAN Converter serves as the
IRIS-Net
IRIS-Net | en