Supervision & Test
The Supervision & Test Dialog integrates functions for testing and monitoring power amps.
You can check control input states and trigger control outputs. A testing generator that provides sine, pink noise and
white noise signal output allows acoustical testing. Status indicators for general power amp operation, the two
amplifier channels and the load connected, indicate whether everything is okay or where failures occurred. You have
the option to choose, which errors are combined and indicated in a general fault message.
A click on the Supervision & Test tab selects the page while in the Setup & Control Window.
CONTROL INPUTS AND CONTROL OUTPUTS
Element
Description
This dialog indicates the actual states of the two freely programmable control inputs IN1 and IN2.
A green indicator signals "not active", i.e. the control input is open or "high". A red indicator signals
"active", in that case the control input is connected to the ground or "low".
This dialog is for manually controlling the two Open Collector control outputs OUT1 and OUT2.
Not engaged (blue) indicates that the control output is deactivated or highly resistive while engaged
(red) indicates that the control output is activated and connected to the ground (closed).
HINT: When a control output has already been programmed, the programmed function defines the
state of the control output and manual control is not possible.
For detailed explanation on how to program control inputs and outputs please refer to chapter Config & Info.
TEST GENERATOR PARAMETERS
The test generator allows outputting a selected test-tone at an adjustable level via the power amps channel A and/or
channel B which allows testing the cable run from the amplifier output to the connected loudspeaker systems as well
as testing the functionality of the loudspeaker components