Combined: This condition allows logically combining up to four other conditions. Logical operators that can be used
are AND, OR and XOR. The conditions result is true (or false when choosing Invert Condition instead) if the logic
operation of the selected condition is true.
Example:
The screenshot on the left shows the condition "TpInf_OK". This conditions result is true as long as the temperature
has not exceeded the upper limit value and at the same time no error has occurred at the interfaces of the N8000. This
is achieved by inverting Condition 1 "TempHigh" and Condition 2 "EInterface" and combining the results with the logic
operation AND.
IRIS-Net
DIGITAL MATRIX | en 511
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956