Standard gateway
192.168.1.1
Telnet port
23
Username
netmax
Password
netmax
A Telnet session can be established with an application such as Windows HyperTerminal. Log in requires the username
and password (default values given in above table) after which the ASCII Control Protocol can be started with the
command "parser". If there is already another ASCII Control Protocol up and running, a new ASCII Control Protocol
session can be forced by using the command "parser -f". The command string "*** <device> command mode entered
***" will be displayed when the ASCII Control Protocol has started successfully. The device is now ready for ASCII
Control Protocol communication.
ASCII CONTROL PROTOCOL
A simple ASCII string protocol, which is referred to as ASCII Control Protocol is implemented in the device. Commands
are organized in a tree structure with up to 5 levels. The slash "/" or a space " " can be used for separation. The
question mark "?" can be utilized to query parameter settings or commands of the corresponding level. To step down
one level you have to enter "..". Use "/" to get back to level 1.
The following table lists the ASCII Control Protocol commands with brief explanations.
Commands for RS-232 communication
Read
Write
Values
Description
/COMM
/LINEFEED
R / W
ON, OFF
Linefeed state for RS-232 communication
/PROMPT
R / W
ON, OFF
Prompt state for RS-232 communication
/ECHO
R / W
ON, OFF
Echo state for RS-232 communication
/LOG
/state
R / W
ALL_ON,
COMMANDS_ON, OFF
Log state for RS-232 communication
/CLEAR
execute
none
Deletes the existing log file
execute
none
Displays the existing log file
/SAVE
execute
none
Saves the log to a file "parser.log" in
directory /flash/log
IRIS-Net
DIGITAL MATRIX | en 456
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956