NUMBER OF LOGIC VALUES
Enter the number of logic values of the task engine to be available via the ASCII
control protocol.
NUMBER OF ANALOG VALUES
Enter the number of analog values of the task engine to be available via the ASCII
control protocol.
IS ALIVE PERIOD (s)
Enter the is alive period of the ASCII control protocol in seconds.
DPM 4000 INTERFACE
Please see section below for details about purpose and configuration.
ENABLE
Set the checkbox to activate the RS-232 interface between a DPM 4000 and the
DPM 8016.
AUDIO OUTPUT
Select the audio output of the DPM 8016, that should output the audio signal to
the DPM 4000.
AUDIO INPUT
Select the audio input number of the DPM 4000.
MEMOFLAG BROKEN LINE
The DPM 4000 memo flag selected here is used for supervising the RS-232
connection.
CONTROL PORT
Clicking with the right mouse button on the corresponding symbol of a control
input provides the configuration dialog of this control input. (not yet activated)
Displays the control inputs’ current condition.
It is possible to manually change the condition of the control outputs (normally
open contact / normally closed contact). Depending on their according
configuration, control outputs are only switched as long as the mouse button is
pressed.
Clicking with the right mouse button on the corresponding symbol of a control
output provides opens the configuration dialog of this control output. (not yet
activated)
DPM 4000 Interface
The DPM 4000 interface of the DPM 8016 gives the possibility of extending an existing Promatrix 4000 system by
additional zones / call stations / amplifier power, etc.
Following hardware is required:
–
a DPM 8016 controller with modules
–
at least one DPC call station
–
at least one DPA amplifiers
DCS 400 relay cards are optional. The DPC 8015 call station enables to do announcements into the existing Promatrix
4000 zones and new Promatrix 8000 zones. Background music (BGM) assignment is also possible from the DPC 8015.
The Promatrix 4000 system may be seen as time master for the complete system. Control communication between the
two systems is done via the RS-232 interface. Audio transmission is done from an AO-1 audio output module of the
DPM 8016 to a Mic/Line input of the DPM 4000.
Configuration
The configuration of the DPM 4000 interface is done in the corresponding section of the DPM 8016 Interfaces dialog.
When selecting the checkbox “ENABLE” a specific topology with 100 zones is created automatically. Please take care
to start with this topology, as then the first 100 zones are reserved for the Promatrix 4000 system. Existing zones may
be deleted.