PROTE
CT
R / W
ON, OFF,
"new Pass-
word"
Read if an owner password is already
defined (ON, OFF). Write "new
Password" to define a new password
(up to 16 characters). Writing is only
possible if /PRE- SET/OWNER/
PASSWORD is "OK".
Commands for Control Inputs/Control
Outputs
/
CONTRO
L
/IN1
/STATE
R
ON, OFF
State of the control input
/ON
/TIME
R / W
0...10.0 [s]
Delay / debounce time during activation
/FNCT
R / W
NOTHING,
POWER,
ABS, REL,
TOG- GLE,
PRESET,
MONI,
MEMFLAG,
MEAS,
TEST- GEN
Function during activation.
For further details please refer to the
table "Control Inputs - GPI Functions"
below.
/PRM
/...
Parameter and values for the functions
mentioned before
/OFF
...
(same as above but for the deactivation
of control inputs)
/IN2
...
(same as above but for the control input
2)
/OUT1
/STATE
R / W
ON, OFF
State of the Control Output
/ON
/TIME
R / W
0...10.0 [s]
Delay / debounce time for the
programmed condition
/FNCT
R / W
NOTHING,
POWER,
ABS, TEMP,
VU, CTL_IN,
ERR- FLAG,
MEMFLAG,
PRESET
Condition that activates a control
output.
For further details please refer to the
table "Control Outputs - GPO Functions"
on this page.
/INV
R / W
ON, OFF
Inverts the result of the programmed
condition