Master/Slave Settings
Element
Default
Description
MODE
off
The master/slave settings only work if more than one DSP 600 device
is connected to a network. Devices that are Master or Slave have
always identical parameter settings.
Select „Master“, if this DSP 600 should write the parameter settings
to one or more other DSP 600 (Slave). Select „Slave“, if the
parameter settings of this DSP 600 should be read from another DSP
600 (master). Select „off“, if the parameter settings of this DSP 600
should be independent from other devices.
NETWORK ID
0
Each master DSP 600 connected to the network must have an unique
network id. Enter the id of the Master DSP 600 the parameters
should be read from if this DSP 600 is used as „Slave“. Multiple DSP
600s can be Slaves to a single Master, if desired.
all groups
selected
If the MODE „Slave“ is selected, choose the parameter groups that
this DSP 600 should read from the Master DSP 600. Following groups
are available:
D: Parameters of the device
A or B: Parameters of input A or B
1 to 6: Parameters of output 1 to 6
Input Settings
Element
Default
Range
Description
MODE
Analog
Analog,
AES/EBU
Select the analog or the digital (AES/EBU) audio inputs of the DSP
600.
INPUT GAIN
0 dB
-60 to +12 dB Adjust the input gain of the audio input.
ADC OVFL
The LED lights red for 2 seconds if there is an overflow of the A/D
converter.
-6dB PAD
off
on, off
Input levels to the DSP 600 can be reduced 6dB prior to the A/D
converter to compensate for higher-level output from mixers and
other audio devices. For ideal signal to noise performance when
connecting the DSP 600 to high output level devices engage the 6dB
PAD („on“) rather than turning down the output of the connected
device.
Digital Input
Element
Default
Range
Description
LOCKED, ERROR
If the LOCKED LED lights green, the input is synchronized to the
incoming signal and the audio is correctly transmitted. When signal
transmission fails, the ERROR LED lights red.
AES/EBU SAMPLE
RATE
-
32 to 192
kHz
Shows the sampling rate of the incoming signal when the input has
been successfully synchronized.
IRIS-Net
DIGITAL SOUND PROCESSOR | en 608
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956