PILOT_A,
PILOT_B
set, when pilot tone monitoring returns errors
DIRTY
set, when the actual preset has been edited but has not been saved yet
PWRGOOD
set, when Power Good interpretation returns errors
CANPOLL
set, when the CAN Polling timed out
BRIDGED
set, when the power amp is operated in Bridged Mode (only with
P3000RL)
COLLECT
set, when the amp's Collected Error Flag is ON
GLOBAL
set, when the amp's External Amplifier Error Flag is ON
MEAS
set, when the internal testing generator has been activated for output
load measurement
Z_VLD_A,
Z_VLD_B
set, when output load measuring is not possible because of missing or
too low signal
EEPROM
set when there is an error in EEPROM administration
PRSGATE
if not set, only limited preset changes are possible
PLT_IN_A,
PLT_IN_B
set, when the 19kHz pilot tone signal applied to the amplifier input is
not recognized
PLT_OUT_A,
PLT_OUT_B
set, when the 19kHz pilot tone signal applied to the amplifier output is
not recognized
MEMFLAG
Interpretation results in "true", when the actual state of the selected
memo flags resembles the reference pattern.
../PRM/MASK NONE, 1...16
Selects memo flags to be interpreted (listing)
../PRM/
VALUE
NONE, 1...16
Defines the expected reference pattern for memo flags
PRESET
Interpretation results in "true", when the actual preset is identical to a
selected preset.
../PRM/DIRTY ON, OFF
Selection is also valid, when parameters have been changed (dirty)
../PRM/USER NONE, 1...8
List of selected user presets
../PRM/FACT NONE, 1
List of selected factory presets
Firmware Upgrade
The firmware of EV remote amps is stored in a FLASH-memory chip. This technology has been chosen to be able to pro-
vide the users with new software without the hassle of physically exchanging memory chips inside of a remote
amplifier. Using IRIS-Net, upgrading the firmware is possible via the CAN Remote Control Interface. In this way you can
install new firmware and future software extensions to always keep your EV Remote Amplifier System up-to-date.
IRIS-Net
REMOTE AMPLIFIER | en 170
Bosch Security Systems B.V.
User Manual
2017.05 | 3.20 | F.01U.119.956