Description
Reset
Type
Name
Bit/Field
4th Sample Input Select
The
MUX3
field is used during the fourth sample of a sequence executed
with the sample sequencer. It specifies which of the analog inputs is
sampled for the analog-to-digital conversion.
0x0
RW
MUX3
15:12
3rd Sample Input Select
The
MUX2
field is used during the third sample of a sequence executed
with the sample sequencer. It specifies which of the analog inputs is
sampled for the analog-to-digital conversion.
0x0
RW
MUX2
11:8
2nd Sample Input Select
The
MUX1
field is used during the second sample of a sequence
executed with the sample sequencer. It specifies which of the analog
inputs is sampled for the analog-to-digital conversion.
0x0
RW
MUX1
7:4
1st Sample Input Select
The
MUX0
field is used during the first sample of a sequence executed
with the sample sequencer. It specifies which of the analog inputs is
sampled for the analog-to-digital conversion.
0x0
RW
MUX0
3:0
June 18, 2014
1110
Texas Instruments-Production Data
Analog-to-Digital Converter (ADC)