Table 27-55. Auto-Negotiation Fast Link Pulse (FLP) Timing
Unit
Max
Nom
Min
Parameter Name
Parameter
Parameter No.
µs
-
125
-
Clock pulse to clock pulse period
T
CLKP
N72
µs
-
62
-
Clock Pulse to Data Pulse Period
T
CLKDP
N73
ns
-
110
-
Clock, Data Pulse Width
T
PUL
N74
ms
-
16
-
FLP Burst to FLP Burst Period
T
BRSTP
N75
ms
-
2
-
Burst Width
T
BRSTW
N76
Figure 27-39. Auto-Negotiation Fast Link Pulse Timing
Fast Link
Pulse(s)
N75
FLP Burst
Clock
Pulse
Data
Pulse
Clock
Pulse
N74
N74
N73
N72
FLP Burst
N76
N76
Table 27-56. 100Base-TX Signal Detect Timing
Unit
Max
Nom
Min
Parameter Name
Parameter
Parameter No.
µs
100
-
-
SD Internal Turn-on Time
T
ON
N79
µs
200
-
-
Internal Turn-off Time
T
OFF
N80
Figure 27-40. 100Base-TX Signal Detect Timing
N79
PMD Input Pair
Signal Detect
(Internal)
N80
June 18, 2014
1874
Texas Instruments-Production Data
Electrical Characteristics