Description
Reset
Type
Name
Bit/Field
3rd Sample Differential Input Select
Description
Value
The analog inputs are not differentially sampled.
0
The analog input is differentially sampled. The corresponding
ADCSSMUXn
nibble must be set to the pair number "i", where
the paired inputs are "2i and 2i+1".
1
Because the temperature sensor does not have a differential option,
this bit must not be set when the
TS2
bit is set.
0
RW
D2
8
2nd Sample Temp Sensor Select
Description
Value
The input pin specified by the
ADCSSMUXn
register is read
during the second sample of the sample sequence.
0
The temperature sensor is read during the second sample of
the sample sequence.
1
0
RW
TS1
7
2nd Sample Interrupt Enable
Description
Value
The raw interrupt is not asserted to the interrupt controller.
0
The raw interrupt signal (
INR0
bit) is asserted at the end of the
second sample's conversion. If the
MASK0
bit in the
ADCIM
register is set, the interrupt is promoted to the interrupt controller.
1
It is legal to have multiple samples within a sequence generate interrupts.
0
RW
IE1
6
2nd Sample is End of Sequence
Description
Value
Another sample in the sequence is the final sample.
0
The second sample is the last sample of the sequence.
1
It is possible to end the sequence on any sample position. Software
must set an
ENDn
bit somewhere within the sequence. Samples defined
after the sample containing a set
ENDn
bit are not requested for
conversion even though the fields may be non-zero.
0
RW
END1
5
2nd Sample Differential Input Select
Description
Value
The analog inputs are not differentially sampled.
0
The analog input is differentially sampled. The corresponding
ADCSSMUXn
nibble must be set to the pair number "i", where
the paired inputs are "2i and 2i+1".
1
Because the temperature sensor does not have a differential option,
this bit must not be set when the
TS1
bit is set.
0
RW
D1
4
June 18, 2014
1132
Texas Instruments-Production Data