Description
Reset
Type
Name
Bit/Field
Action for Counter=
LOAD
This field specifies the action to be taken when the counter matches the
value in the
PWMnLOAD
register.
Description
Value
Do nothing.
0x0
Invert pwmA.
0x1
Drive pwmA Low.
0x2
Drive pwmA High.
0x3
0x0
RW
ACTLOAD
3:2
Action for Counter=0
This field specifies the action to be taken when the counter is zero.
Description
Value
Do nothing.
0x0
Invert pwmA.
0x1
Drive pwmA Low.
0x2
Drive pwmA High.
0x3
0x0
RW
ACTZERO
1:0
June 18, 2014
1726
Texas Instruments-Production Data
Pulse Width Modulator (PWM)