Description
Reset
Type
Name
Bit/Field
SS0 Trigger Select
This field selects the trigger source for Sample Sequencer 0
The valid configurations for this field are:
Event
Value
Processor (default)
The trigger is initiated by setting the
SSn
bit in the
ADCPSSI
register.
0x0
Analog Comparator 0
This trigger is configured by the
Analog Comparator Control
0 (ACCTL0)
register (page 1665).
0x1
Analog Comparator 1
This trigger is configured by the
Analog Comparator Control
1 (ACCTL1)
register (page 1665).
0x2
Analog Comparator 2
This trigger is configured by the
Analog Comparator Control
2 (ACCTL2)
register (page 1665).
0x3
External (GPIO Pins)
This trigger is connected to the GPIO interrupt for the
corresponding GPIO (see “ADC Trigger Source” on page 750).
0x4
Timer
In addition, the trigger must be enabled with the
TnOTE
bit
in the
GPTMCTL
register (page 986).
0x5
PWM generator 0
The PWM generator 0 trigger can be configured with the
PWM0 Interrupt and Trigger Enable (PWM0INTEN)
register
0x6
PWM generator 1
The PWM generator 1 trigger can be configured with the
PWM1INTEN
register (page 1713).
0x7
PWM generator 2
The PWM generator 2 trigger can be configured with the
PWM2INTEN
register (page 1713).
0x8
PWM generator 3
The PWM generator 3 trigger can be configured with the
PWM3INTEN
register (page 1713).
0x9
reserved
0xA-0xD
Never Trigger (No triggers are allowed to the ADC digital
interface)
0xE
Always (continuously sample)
0xF
0x0
RW
EM0
3:0
1095
June 18, 2014
Texas Instruments-Production Data
Tiva
™
TM4C1294NCPDT Microcontroller