306
8 COMMON FUNCTIONS
8.3 Module Data Backup Function
8.3
Module Data Backup Function
When buffer memory data is rewritten with programs or others, the setting values in the module extension parameter file and
the execution data being used in control (buffer memory data) may differ. In cases like this, the execution data will be lost if the
CPU module is powered off.
For the cases like this, the module data backup function writes the execution data into the module extension parameter file
and backs up the data. The data in the module extension parameter file that was backed up will be written into the buffer
memory when the power is turned on next time.
Module backing up means
This function is executed with a program.
Control details
The following table lists the data that can be backed up with the module data backup function.
*1 For the parameter file, refer to the following.
*2 The storage destination of module extension parameters is specified by the extension parameter storage setting. For details, refer to the
following.
Page 487 Extended parameter storage setting
*3 The module data backup can be performed only while the CPU module status is STOP.
Control precautions
• Write data into the flash ROM only when the positioning control is not performed (when PLC READY signal [Y0] is off). If
the initialization is executed while PLC READY signal [Y0] is on, PLC READY ON write (Warning code: 0905H) will occur.
• Writing to the flash ROM can be executed up to 100000 times. If the number of writing to the flash ROM exceeds 100000
times, writing data to the flash ROM may become impossible and Flash ROM write error (Error code: 1931H) will occur.
• The number of module data backups using a program after the power is turned on once or the CPU module is reset is
limited to up to 25 times (including the number of executions of the module data initialization function). If the writing
operation is executed 26th times, Flash ROM write number error (Error code: 1080H) will occur. If this error occurs, reset
the error, power off and on the module again, or reset the CPU module.
Control restrictions
• When the extension parameter storage setting has been set to "CPU", the module data backup can be performed only
while the CPU module status is STOP. Use "[Cd.1] Module data backup request" for the module data backup.
• Do not turn on and off the power or reset the CPU module during the writing processing to the flash ROM. Doing so cancels
the flash ROM write and the backed up data will be lost.
Parameter
Extension parameter storage setting
CPU module
Positioning module
Module parameter
No data is backed up.
Module extension parameter
The module extension parameters in the buffer memory
are backed up in the module extension parameter file of
the CPU module.
The module extension parameters in the buffer memory
are backed up in the module extension parameter file of
the positioning module.
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......