3 MAJOR POSITIONING CONTROL
3.1 Overview of the Major Positioning Controls
Checking the current value
Values indicating the current values
In the RD75, the following two types of address are used as values to indicate the position.
These addresses (Current feed value and Machine feed value) are stored in the monitor data area, and used for monitoring
the current value display.
Current feed value and Machine feed value are used for monitoring the current value display.
Restrictions
When the stored Current feed value is used for the control, an error of 0.88ms will occur in the update timing of the current
value. When the stored Machine feed value is used for the control, an error of 0.88ms will occur in the update timing of the
current value.
Item
Description
Current feed value
• The value stored in [Md.20] Current feed value.
• This value has an address established with Machine OPR as a reference. However, the address can be changed by
changing the current value.
• This value is updated every 0.88ms.
Machine feed value
• The value stored in [Md.21] Machine feed value.
• This value always has an address established with Machine OPR as a reference. The address cannot be changed even if
the current value is changed to a new value.
• This value is updated every 0.88ms.
0
V
20000
0
10000
10000
t
1 to
Current feed value
OP
The current value has been changed
to 20000 with the current value change.
1 to
Machine feed value
The address after the current value
change is stored.
The address does not change even
after the current value has been changed.
Md.20
Md.21
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......