312
8 COMMON FUNCTIONS
8.7 Amplifier-less Operation Function
8.7
Amplifier-less Operation Function
With this function, user programs can be debugged at a start-up or positioning operations can be simulated by inputting a
false external input signal from the buffer memory. External wiring with a drive unit or a limit switch is not required.
Control details
To use this function, switch the operation mode from the normal operation mode to the amplifier-less operation mode.
If the operation mode is switched from the amplifier-less operation mode to the normal operation mode after the amplifier-less
operation, the normal operation with External I/O signal connected can be performed.
■
Current value
When the operation mode is switched between the normal operation mode and the amplifier-less operation mode, "0" is set in
"[Md.20] Current feed value" and "[Md.21] Machine feed value".
■
External I/O signal
The following table lists "Enabled external input signals" and "Output status of external output signals" in the normal operation
mode and the amplifier-less operation mode.
Operation mode switching between the normal operation mode and the amplifier-less operation mode is
reflected on all axes in a batch. The operation mode cannot be switched for each axis.
Operation mode
Description
Normal operation mode
• The module is in this mode immediately after the power-on.
• In this mode, External I/O signal is connected and the positioning operation is performed.
Amplifier-less operation mode
• In this mode, the setting in [Cd.44] External input signal operation device is used as a false external input
signal and the positioning operation is performed.
• The starting method of positioning control is the same as that in the normal operation mode.
External I/O signal
Normal operation mode
Amplifier-less operation mode
Enabled external input signals
Drive unit READY signal
Input from external devices
Setting in [Cd.44] External input
signal operation device
Stop signal
Upper limit signal
Lower limit signal
Zero signal
Near-point dog signal
External command signal
Manual pulse generator
Input from external devices
Output status of external output
signals
Deviation counter clear
Output to external devices
No output to external devices
Pulse output
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......