1 STARTING AND STOPPING
1.2 Stopping
33
1
*1 When multiple positioning data is executed by the continuous positioning control or continuous path control and there is an invalid
setting value in a positioning data, an error occurs and automatic deceleration is performed at the previous positioning data. In this case,
the sudden stop is not performed even if sudden stop is selected for the stop group 3. If any of the following errors occurs, the operation
is immediately stopped after the execution of the positioning data that is one before the positioning data No. where the error occurred.
No command speed (Error code: 1A13H, 1A14H)
Outside linear movement amount range (Error code: 1A15H, 1A16H)
Large arc error deviation (Error code: 1A17H)
Software stroke limit (+) (Error code: 1A18H, 1A19H)
Software stroke limit (-) (Error code: 1A1AH, 1A1BH)
Sub point setting error (Error code: 1A27H, 1A28H, 1A29H, 1A2AH, 1A37H)
End point setting error (Error code: 1A2BH, 1A2CH)
Center point setting error (Error code: 1A2DH, 1A2EH, 1A2FH)
Outside radius range (Error code: 1A32H)
Illegal setting of ABS direction in unit of degree (Error code: 19A4H, 19A5H)
*2 This indicates Error at switching from normal operation mode to amplifier-less operation mode (Error code: 18B0H) and Error at
switching from amplifier-less operation mode to normal operation mode (Error code: 18B1H).
Classification of the stop processing types
The stop processing during the operation is classified into three types: deceleration stop, sudden stop, and immediate stop.
■
Deceleration stop
This processing is performed using [Pr.10] Deceleration time 0, and [Pr.28] Deceleration time 1 to [Pr.30] Deceleration time 3.
Select any time from Deceleration time 0 to Deceleration time 3 and set the time in [Da.4] Deceleration time No.
■
Sudden stop
This processing is performed using [Pr.36] Sudden stop deceleration time.
■
Immediate stop
This processing does not include deceleration processing. The RD75 immediately stops outputting pulses but the target
moves for the distance of droop pulses of the deviation counter of the drive unit.
Select either deceleration stop or sudden stop for [Pr.37] Stop group 1 sudden stop selection to [Pr.39] Stop
group 3 sudden stop selection in detailed parameter 2. (The factory default setting is Deceleration stop.)
Pr.8
Pr.8
Actual deceleration
time
Set deceleration time
Positioning speed
Actual sudden stop
deceleration time
Sudden stop
deceleration time
Positioning speed
Coasts for the droop pulse in the deviation
counter of drive unit.
Positioning speed
Stop
cause
Stop
cause
Stop
Stop
Stop
Sudden
stop cause
Speed limit value
Speed limit value
(1) Deceleration stop
(2) Sudden stop
(3) Immediate stop
Pr.36
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......