8 COMMON FUNCTIONS
8.6 History Monitor Function
311
8
Error history and warning history
The error history and warning history of past 16 records can be monitored. Once 16 records are stored, the oldest record is
overwritten with the latest record. Therefore, the latest 16 history records are stored at all times.
The error history and warning history can be checked using the intelligent function module monitor window. The following
describes the check method.
1.
Display the "Intelligent Function Module Monitor" window.
[View]
[Docking Window]
[Intelligent Function Module Monitor]
[Intelligent Function Module Monitor 1] to
[Intelligent Function Module Monitor 10]
2.
Select the RD75 from the project view.
3.
Right-click
Select [Register to Intelligent Function Module Monitor] in the shortcut menu.
4.
Select the RD75 from the "Module List" in "Module Information Selection" window.
5.
In "Monitor Item Category List", select "Display by Axis Unit" or "Display by Item Unit", and click the [OK] button.
6.
Select [Online]
[Watch]
[Start Watching].
7.
In the registered "Intelligent Function Module Monitor" window, right-click "Error History" or "Warning History", and select
[Detailed Dialog] in the shortcut menu. "Error History" or "Warning History" is displayed.
The error history and warning history can be checked using the positioning monitor. For details on the positioning monitor,
refer to the following.
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......