274
7 CONTROL SUB FUNCTIONS
7.8 Function Related to Stop
Step start request
The control stopped by a step operation can be continued by using Step start request. (Step start request is set in the control
data [Cd.36] Step start request.) Once accepted, the setting of [Cd.36] Step start request is automatically cleared.
The following table shows the results of starts using the step start request during the step operation.
Step not possible (Warning code: 0996H) will occur and the step operation will not be continued if [Md.26] Axis operation
status is other than Step standby or Step valid flag is off when the step start request is set.
Using the step operation
The following figure shows the procedure for checking positioning data in the step operation.
Stop state in the step operation
[Md.26] Axis operation
status
[Cd.36] Step start request
Result of step starts
The positioning of the step operation has
normally stopped.
Step standby
1: Step continue
The next positioning data No. is
performed.
The positioning of the step operation has
not normally stopped.
(due to stop signal or an error)
Stopped
Error
1: Step continue
Step not possible (Warning code: 0996H)
YES
YES
YES
NO
NO
NO
Write "1: Carry out step operation" in Cd.35 Step valid flag.
Set Cd.34 Step mode.
Write "0: Not carry out step operation" in Cd.35 Step valid flag.
Write "1: Restart" in Cd.6 Restart command, and check that the stopped
positioning data operates properly.
Write "1: Step continue" in Cd.36 Step start request, and check that
the next positioning data operates properly.
Start
Turn on Step valid flag.
Set step mode.
Start positioning.
The operation
stopped with an error.
One step of
the positioning is normally
completed.
Restart positioning.
All positioning is completed.
Continue the step operation.
Turn off Step valid flag.
End
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......