12 DATA USED FOR POSITIONING CONTROL
12.8 Control Data
[Cd.27] Target position change value (new address)
Set a new positioning address to change the target position during positioning.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Setting range
The setting range depends on the setting of [Pr.1] Unit setting.
■
Default value
The default value is 0 for all the axes.
[Cd.28] Target position change value (new speed)
Set a new speed to change the target position during positioning. When 0 is set, the speed is not changed.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Setting range
The setting range depends on the setting of [Pr.1] Unit setting.
■
Default value
The default value is 0 for all the axes.
[Cd.29] Target position change request flag
Set whether to change the target position during positioning.
• The target position is changed by setting 1: Target position change request for this area.
• After the target position is changed, 0 is automatically stored. Storing 0 indicates the completion of the target position
change.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Default value
The default value is 0 for all the axes.
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Cd.27] Target position change value (new address)
1534
1634
1734
1834
1535
1635
1735
1835
Setting of [Pr.1] Unit setting
Setting value with programs (ABS)
Setting value with programs (INC)
0: mm
-2147483648 to 2147483647 (
10
-1
m)
-2147483648 to 2147483647 (
10
-1
m)
1: inch
-2147483648 to 2147483647 (
10
-5
inches)
-2147483648 to 2147483647 (
10
-5
inches)
2: degree
0 to 35999999 (
10
-5
degrees)
-2147483648 to 2147483647 (
10
-5
degrees)
3: pulse
-2147483648 to 2147483647 (pulse)
-2147483648 to 2147483647 (pulse)
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Cd.28] Target position change value (new speed)
1536
1636
1736
1836
1537
1637
1737
1837
Setting of [Pr.1] Unit setting
Setting value with programs
0: mm
0 to 2000000000 (
10
-2
mm/min)
1: inch
0 to 2000000000 (
10
-3
inches/min)
2: degree
0 to 3000000000 (
10
-3
degrees/min)
3: pulse
0 to 5000000 (pulse/s)
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Cd.29] Target position change request flag
1538
1638
1738
1838
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......