12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data
[Md.22] Feedrate
This area stores the command output speed of the operating workpiece. The stored value may be different from the actual
motor speed during operation. Multiplying the stored value by the following converted value enables the monitoring of the
converted value in each unit.
• During interpolation operation, the composite speed or reference axis speed is stored for the reference axis and 0 is stored
for the interpolation axis.
• The update cycle of this area is 0.88ms.
■
Buffer memory address
The following table shows the buffer memory address of this area.
[Md.23] Axis error No.
When an error is detected, this area stores the error code corresponding to the error. Monitor the value in hexadecimal.
• The latest error code is stored at all times and when a new error occurs, the error code is overwritten.
• When [Cd.5] Axis error reset (axis control data) is turned on, the error code is cleared to 0.
■
Buffer memory address
The following table shows the buffer memory address of this area.
[Md.24] Axis warning No.
When a warning is detected, this area stores the warning code corresponding to the warning. Monitor the value in
hexadecimal.
• The latest warning code is stored at all times and when a new warning occurs, the warning code is overwritten.
• When [Cd.5] Axis error reset (axis control data) is turned on, the warning code is cleared to 0.
■
Buffer memory address
The following table shows the buffer memory address of this area.
[Md.25] Valid M code
This area stores the M code that is currently valid (i.e. set to the positioning data relating to the current operation).
• The range of the stored value is 0 to 65535.
• This area is updated when M code ON signal [X4, X5, X6, X7] turns on.
• When PLC READY signal [Y0] is turned off, 0 is stored.
■
Buffer memory address
The following table shows the buffer memory address of this area.
Unit
Converted value
mm/min
10
-2
inch/min
10
-3
degree/min
10
-3
pulse/s
1
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Md.22] Feedrate
804
904
1004
1104
805
905
1005
1105
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Md.23] Axis error No.
806
906
1006
1106
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Md.24] Axis warning No.
807
907
1007
1107
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Md.25] Valid M code
808
908
1008
1108
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......