14 TROUBLESHOOTING
14.5 List of Error Codes
543
14
1AB1H
Acceleration
time 1 setting
error
A value outside the setting range is set in [Pr.25] Acceleration
time 1 of detailed parameter 2.
[Operation of when the error has occurred]
■
At power-on or at turning on of PLC READY signal [Y0]
RD75 READY signal [X0] does not turn on.
■
At the start of operation
The operation is not performed.
■
During operation
The operation stops according to the setting of [Pr.39] Stop
group 3 sudden stop selection of detailed parameter 2
(deceleration stop/sudden stop). (for manual pulse generator
operation, deceleration stop only)
Correct the value within the setting range and turn on PLC
READY signal [Y0] if the signal is off. For details, refer to
Page 400 [Pr.25] Acceleration time 1 to [Pr.27]
1AB2H
Acceleration
time 2 setting
error
A value outside the setting range is set in [Pr.26] Acceleration
time 2 of detailed parameter 2.
[Operation of when the error has occurred]
■
At power-on or at turning on of PLC READY signal [Y0]
RD75 READY signal [X0] does not turn on.
■
At the start of operation
The operation is not performed.
■
During operation
The operation stops according to the setting of [Pr.39] Stop
group 3 sudden stop selection of detailed parameter 2
(deceleration stop/sudden stop). (for manual pulse generator
operation, deceleration stop only)
Correct the value within the setting range and turn on PLC
READY signal [Y0] if the signal is off. For details, refer to
Page 400 [Pr.25] Acceleration time 1 to [Pr.27]
1AB3H
Acceleration
time 3 setting
error
A value outside the setting range is set in [Pr.27] Acceleration
time 3 of detailed parameter 2.
[Operation of when the error has occurred]
■
At power-on or at turning on of PLC READY signal [Y0]
RD75 READY signal [X0] does not turn on.
■
At the start of operation
The operation is not performed.
■
During operation
The operation stops according to the setting of [Pr.39] Stop
group 3 sudden stop selection of detailed parameter 2
(deceleration stop/sudden stop). (for manual pulse generator
operation, deceleration stop only)
Correct the value within the setting range and turn on PLC
READY signal [Y0] if the signal is off. For details, refer to
Page 400 [Pr.25] Acceleration time 1 to [Pr.27]
1AB4H
Deceleration
time 1 setting
error
A value outside the setting range is set in [Pr.28] Deceleration
time 1 of detailed parameter 2.
[Operation of when the error has occurred]
■
At power-on or at turning on of PLC READY signal [Y0]
RD75 READY signal [X0] does not turn on.
■
At the start of operation
The operation is not performed.
■
During operation
The operation stops according to the setting of [Pr.39] Stop
group 3 sudden stop selection of detailed parameter 2
(deceleration stop/sudden stop). (for manual pulse generator
operation, deceleration stop only)
Correct the value within the setting range and turn on PLC
READY signal [Y0] if the signal is off. For details, refer to
Page 400 [Pr.28] Deceleration time 1 to [Pr.30]
1AB5H
Deceleration
time 2 setting
error
A value outside the setting range is set in [Pr.29] Deceleration
time 2 of detailed parameter 2.
[Operation of when the error has occurred]
■
At power-on or at turning on of PLC READY signal [Y0]
RD75 READY signal [X0] does not turn on.
■
At the start of operation
The operation is not performed.
■
During operation
The operation stops according to the setting of [Pr.39] Stop
group 3 sudden stop selection of detailed parameter 2
(deceleration stop/sudden stop). (for manual pulse generator
operation, deceleration stop only)
Correct the value within the setting range and turn on PLC
READY signal [Y0] if the signal is off. For details, refer to
Page 400 [Pr.28] Deceleration time 1 to [Pr.30]
Error
code
Error name
Cause and description
Action
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......