134
3 MAJOR POSITIONING CONTROL
3.2 Positioning Data Setting
Operation chart
The following shows the operation timing of the speed-position switching control (ABS mode).
During the speed control with the speed-position switching control (ABS mode), In speed control flag ([Md.31] Status: b0) is
on.
■
Operation example
The following figure shows the operation when Speed-position switching signal is input at the position where the current feed
value is 90.00000 (degree) during the execution of Forward run speed-position in [Da.2] Control method with the settings as
follows: [Pr.1] Unit setting is 2: degree and [Pr.21] Current feed value during speed control is 1: Current feed value is updated.
(The setting value of [Da.6] Positioning address/movement amount is 270.00000 (degree).)
t
V
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
Positioning start signal
[Y10, Y11, Y12, Y13]
BUSY signal
[XC, XD, XE, XF]
Positioning complete signal
[X14, X15, X16, X17]
Speed-position switching signal
Speed control
Position control
Dwell time
In speed control flag
Md. 31 Status: b0
Cd. 24 Speed-position switching
enable flag
Da. 8 Command speed
Address set in Positioning
address/movement amount
Da. 6
0.00000°
90.00000°
90.00000°
270.00000°
0.00000°
Stop at 270.00000 [degree]
Speed-position
switching signal ON
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......