5 MANUAL CONTROL
5.1 Overview of the Manual Control
175
5
Manual pulse generator operation
In the manual pulse generator operation, the positioning is performed depending on the number of pulses input from the
manual pulse generator. (Pulses for the number of input pulses are output.) This method is used to perform the fine
adjustment manually for the precise positioning and to obtain a positioning address.
■
Sub functions for the manual control
For details on the sub functions that can be combined with the manual control, refer to the following.
MELSEC iQ-R Positioning Module User's Manual (Startup)
For details on each sub function, refer to the following.
Page 209 CONTROL SUB FUNCTIONS
■
Manual control from an engineering tool
The execution of the JOG operation and Inching operation, and setting whether to enable or disable Manual pulse generator
operation can be performed in the test mode of the engineering tool.
■
Monitoring the manual control
The manual control can be monitored using the positioning monitor of the engineering tool. For details on the positioning
monitor, refer to the following.
M
RD75
Manual pulse generator
The object moves according
to the command pulses.
Output pulses
Pulse input
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......