3 MAJOR POSITIONING CONTROL
3.2 Positioning Data Setting
99
3
2-axis circular interpolation control with the sub point specified
In the 2-axis circular interpolation control ([Da.2] Control method = ABS circular sub, INC circular sub), two motors are used to
perform the position control in an arc path passing through specified sub points, while the interpolation is performed for the
axis directions set in each axis.
For details on the interpolation control, refer to the following.
2-axis circular interpolation control with sub point specified (ABS circular sub)
■
Operation chart
In the absolute system and 2-axis circular interpolation control with sub point specified, the positioning is performed from the
current stop position (start point address) to the address (end point address) set in [Da.6] Positioning address/movement
amount in an arc path passing through the sub point address (sub point address) set in [Da.7] Arc address.
The resulting control path is an arc whose center is the intersection point of the perpendicular bisectors of a straight line
between the start point address (current stop position) and sub point address (arc address) and a straight line between the
sub point address (arc address) and end point address (positioning address).
■
Restrictions
In the following cases, the 2-axis circular interpolation control cannot be set.
• When Degree is set in [Pr.1] Unit setting
• When the units set in [Pr.1] Unit setting are different between the reference axis and interpolation axis (The combination of
mm and inch is possible.)
• When Reference axis speed is set in [Pr.20] Interpolation speed specification method
In the following case, an error occurs and the positioning will not start. During the positioning control, the operation stops
immediately at the detection of the error.
Error cause
Error code
When the radius exceeds 536870912 (= 2
29
) (The maximum radius for which
the circular interpolation control is possible is 536870912 (= 2
29
).)
Outside radius range (Error code: 1A32H) occurs at the start of the
positioning.
When the center point address is out of the range of -2147483648 (-2
31
) to
2147483647 (2
31
-1)
Sub point setting error (Error code: 1A37H) occurs at the start of the
positioning.
Start point address = End point address
End point setting error (Error code: 1A2BH)
Start point address = Sub point address
Sub point setting error (Error code: 1A27H)
End point address = Sub point address
Sub point setting error (Error code: 1A28H)
When the start point address, sub point address, and end point address are
on a straight line
Sub point setting error (Error code: 1A29H)
OP
Reverse direction
Forward direction
Arc center point
Movement by circular interpolation
Forward direction
End point address
(arc address)
(positioning address)
Start point address
(current stop position)
Reverse direction
Sub point address
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......