7 CONTROL SUB FUNCTIONS
7.9 Other Functions
289
7
Command in-position function
Command in-position function checks the remaining distance to the stop position during the automatic deceleration of the
positioning control, and sets a flag to 1. This flag is called Command in-position flag. The command in-position flag is used as
a front-loading signal indicating beforehand the completion of the position control.
Control details
The following shows the control details of the command in-position function.
• When the remaining distance to the stop position during the automatic deceleration of the position control becomes equal
to or less than the value set in [Pr.16] Command in-position width, 1 is stored in Command in-position flag ([Md.31] Status:
b2).
• The command in-position width check is performed every 0.88ms.
Control precautions
• The command in-position width check will not be performed in the following cases.
In speed control
In speed control of the speed-position switching control
In speed control of the position-speed switching control
• Command in-position flag will be turned off in the following cases. (0 will be stored in [Md.31] Status: b2.)
At the position control start
At the speed control start
At the start of the speed-position switching control or position-speed switching control
At the OPR control start
At the JOG operation start
At the inching operation start
When the manual pulse generator operation is enabled
• [Pr.16] Command in-position width and Command in-position flag ([Md.31] Status: b2) of the reference axis are used during
the interpolation control. When [Pr.20] Interpolation speed specification method is Composite speed, the command in-
position width check is performed in the remaining distance on the composite axis (line or arc connecting the start point
address and end point address).
V
t
ON
OFF
Md.31
Command in-position
width setting value
Positioning
Command in-position flag
[ Status:
b2
]
Md. 31
V
OFF
ON
t
Command in-position flag
[
Status: b2
]
Speed to position switching
Position
control start
Speed-position
switching control start
Command in-position
width setting value
Execution of the command in-position
width check
Command in-position
width setting value
Execution of the command in-position
width check
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......