382
12 DATA USED FOR POSITIONING CONTROL
12.3 Basic Setting
[Pr.3] Movement amount per rotation (16 bits) (Al)
Set the distance of machine movement (movement amount) per rotation of the motor shaft with 16 bits. When [Pr.62]
Electronic gear selection is set to 0: 16 bits, this area is valid. When the movement amount per rotation of the motor shaft
exceeds the setting range of this area in the system used, adjust the setting value with the following method.
• Use [Pr.4] Unit magnification.
• Use [Pr.3] Movement amount per rotation (32 bits).
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Setting range
The setting range depends on the setting of [Pr.1] Unit setting.
*1 When this buffer memory area is set with programs, a calculation is performed in the RD75 to convert a setting value to the value in
each unit. For setting this buffer memory area, take the value after the unit conversion into consideration.
■
Default value
The default value is 20000 for all the axes.
[Pr.4] Unit magnification
When the movement amount per rotation of the motor shaft exceeds the setting range of [Pr.3] Movement amount per rotation
(16 bits), adjust the setting range (10 to 1000 times) with this area. When [Pr.62] Electronic gear selection is set to 0: 16 bits,
this area is valid. When [Pr.62] Electronic gear selection is set to 1: 32 bits, the unit magnification is fixed to 1: 1 time.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Default value
The default value is 1: 1 time for all the axes.
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Pr.3] Movement amount per rotation (16 bits) (Al)
2
152
302
452
Setting of [Pr.1] Unit setting
Setting value with engineering tools
Setting value with programs
0: mm
0.1 to 6553.5 (
m)
1 to 65535 (
10
-1
m)
1: inch
0.00001 to 0.65535 (inch)
1 to 65535 (
10
-5
inches)
2: degree
0.00001 to 0.65535 (degree)
1 to 65535 (
10
-5
degrees)
3: pulse
1 to 65535 (pulse)
1 to 65535 (pulse)
Unit magnification
Setting value
1 time
1
10 times
10
100 times
100
1000 times
1000
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Pr.4] Unit magnification
3
153
303
453
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......